Skip to main content
Peptides TT home

Lab guide

How to Read a Certificate of Analysis

A section-by-section guide to the peptide certificate of analysis: identity, batch number, MS mass, HPLC purity, TFA, peptide content and red flags.

By Peptides TT Quality Team · Published · Updated

A certificate of analysis (COA) is the document that connects a physical vial to measured analytical data. For a research laboratory it is the primary evidence that a material is what the label says it is, at the quality the specification requires. Reading one properly takes a few minutes and can prevent weeks of work built on the wrong material. This guide walks through each section of a typical peptide COA and lists the warning signs worth looking for.

What a certificate of analysis is for

A COA reports the results of specific tests carried out on one specific production lot. It is not a product brochure and it is not a generic specification sheet. Two vials of the same peptide from different lots should come with two different certificates, each showing its own measured values. If a document could apply equally to any lot, it is not really a certificate of analysis.

Identity information

The top of the certificate identifies the material. Expect to see:

  • Product name, often with a common synonym. For example, Angiotensin II or Bradykinin.
  • Amino acid sequence, written in one-letter or three-letter code, including any terminal modifications such as C-terminal amidation (-NH2) or N-terminal pyroglutamate (pGlu).
  • CAS number, the Chemical Abstracts Service registry identifier. It should match the specific form of the peptide; salt forms and modified analogues can carry different numbers.
  • Molecular formula, such as C50H71N13O12, which should be consistent with the stated sequence.
  • Theoretical molecular weight, calculated from the formula. Check whether the value given is the average mass or the monoisotopic mass, as they differ slightly.

Lot or batch number

The batch number (sometimes called lot number) is the most important line on the page. It ties every result on the certificate to one production run. Without it, none of the data can be linked to the vial in your hands.

Analytical results

Most peptide certificates present results in a table with three columns: test, specification and result.

TestTypical specificationWhat it tells you
AppearanceWhite to off-white lyophilized powderGross physical condition
Identity by MSObserved mass consistent with theoreticalThe correct molecule is present
Purity by HPLC≥95% or ≥98% (area %)Proportion of the main component among UV-detected species
Counter-ion contentReported, often as TFA %Non-peptide mass in the solid
Peptide contentReported as % w/wHow much of the weighed solid is peptide
Water contentReported as % w/wResidual moisture after lyophilization

Molecular weight: theoretical versus observed

Identity is usually confirmed by mass spectrometry. The certificate should report the observed mass alongside the theoretical value. A small difference within the instrument's tolerance is normal. A difference of about +16 Da can indicate methionine oxidation; −17 or −18 Da can suggest pyroglutamate formation or loss of water; a difference equal to one residue mass may point to a deletion sequence.

Purity by HPLC

Purity is normally measured by reversed-phase HPLC with UV detection and reported as area percentage: the area of the main peak divided by the total area of all integrated peaks. A good certificate includes or references the chromatogram and states the method conditions. Our article on peptide purity testing by HPLC and MS explains how these figures are generated and what they can and cannot show.

Counter-ion and TFA content

Peptides purified by reversed-phase HPLC are usually isolated as trifluoroacetate salts, because trifluoroacetic acid is used in the mobile phase. The TFA salt form means positively charged groups (the N-terminus, Arg, Lys, His) carry TFA counter-ions. These add mass to the solid but do not appear in the HPLC purity figure. Some certificates report TFA content directly; others indicate an acetate or hydrochloride salt form where an exchange step has been carried out.

Peptide content versus purity

These two numbers are frequently confused. Purity describes the peptide fraction: of all the peptide-like material detected, how much is the target sequence. Peptide content (net peptide content) describes the whole solid: of every milligram weighed, how much is peptide, as opposed to counter-ions and water. A material can be 98% pure by HPLC and still have a net peptide content of 70–85%. Peptide content is commonly measured by amino acid analysis or elemental nitrogen analysis.

Water content

Residual water, often measured by Karl Fischer titration, is reported as a percentage by weight. Lyophilized peptides typically retain a few percent. Higher values can affect stability and weighing accuracy, which is one reason careful storage matters; see our guide to peptide storage and stability.

Dates and sign-off

Look for the date of manufacture, the date of analysis and, where given, a retest date. Test dates should fall after manufacture. The certificate should be reviewed and approved by named quality functions, typically a quality control analyst and a quality assurance approver, with signatures or an equivalent controlled electronic approval.

Matching the certificate to the vial

Before any material is used, confirm that:

  1. The batch number on the vial label is identical to the batch number on the certificate, character for character.
  2. The product name and sequence agree.
  3. The quantity on the label is consistent with what was ordered.
  4. The certificate is retained in your inventory records and linked to every aliquot made from that vial.

If any of these do not match, set the material aside and contact the supplier before proceeding.

Red flags

Be cautious about a certificate if you notice any of the following:

  • No batch number, or a batch number that does not match the vial
  • Identical purity figures, to two decimal places, across different lots
  • An observed mass identical to the theoretical value to many decimal places, with no instrument details
  • No chromatogram, no method conditions and no indication of the detection wavelength
  • A molecular formula that does not match the stated sequence or molecular weight
  • Test dates that precede the manufacture date
  • Missing approval or signatures, inconsistent fonts or signs of editing
  • Purity claimed as 100%, which no real chromatographic method supports

Summary

A certificate of analysis is only useful when it is lot-specific, internally consistent and matched to the vial in hand. Check identity, batch number, theoretical and observed mass, HPLC purity, counter-ion and peptide content, water content, dates and approval. Browse products such as Neurotensin in our vasoactive and neuropeptide ranges, or read more about how each lot is characterised on our Quality and Testing page.

RESEARCH USE ONLY

For research use only. Not for human or veterinary use. Not a drug, food, supplement or cosmetic. Not intended to diagnose, treat, cure or prevent any disease.

Peptides mentioned in this guide

  • Sealed glass vial of lyophilized Tirzepatide research peptide, 30 mg, on a navy background

    CAS 2023788-19-2

    In stock

    Tirzepatide

    Dual GIP/GLP-1 receptor agonist peptide studied in metabolic research, supplied as a 30 mg lyophilized vial for in-vitro and analytical work.

    Purity
    Per batch COA
    Vial
    30 mg

    TT$2,000.00indicative

  • Sealed glass vial of lyophilized Retatrutide research peptide, 20 mg, on a navy background

    CAS 2381089-83-2

    In stock

    Retatrutide

    Investigational GIP, GLP-1 and glucagon triple receptor agonist peptide, supplied as a 20 mg lyophilized vial for in-vitro metabolic research.

    Purity
    Per batch COA
    Vial
    20 mg

    TT$2,200.00indicative

  • Sealed glass vial of lyophilized Tesamorelin research peptide, 10 mg, on a navy background

    CAS 218949-48-5

    In stock

    Tesamorelin

    Synthetic GHRH analogue: the 44-residue human GHRH sequence with an N-terminal trans-3-hexenoyl group, supplied as a 10 mg lyophilized vial.

    Purity
    Per batch COA
    Vial
    10 mg

    TT$1,200.00indicative