Mass Spectrometry (MS)

Mass spectrometry (MS) is an analytical technique that ionises molecules and measures their mass-to-charge ratio, used to confirm that a peptide has the expected molecular mass.

Also known as: MS, ESI-MS, MALDI-TOF MS

Mass spectrometry (MS) measures the mass of molecules by converting them into charged ions and recording how they move in electric or magnetic fields. For synthetic peptides, its main job is identity confirmation: showing that the material in the vial has the molecular mass expected from its sequence.

How it works

A mass spectrometer has three basic parts: an ion source, a mass analyser and a detector. Two ionisation methods dominate peptide work:

  • Electrospray ionisation (ESI) sprays a solution of the peptide through a charged needle. Peptides often pick up several protons, producing a series of multiply charged ions. Software deconvolutes this series back to a single neutral mass.
  • Matrix-assisted laser desorption/ionisation (MALDI) mixes the peptide with a light-absorbing matrix, dries it on a plate and fires a laser at it. MALDI usually produces singly charged ions and is often paired with a time-of-flight (TOF) analyser.

The instrument reports the mass-to-charge ratio (m/z) of each ion. From that, the analyst calculates the observed mass and compares it with the theoretical molecular weight.

Why it matters in the lab

HPLC can tell you how much of a sample is one main component, but not what that component is. MS fills the gap. If the observed mass matches the calculated value within the instrument's tolerance, the main species is consistent with the intended sequence. A mismatch can reveal a missing residue, an incomplete deprotection or an unexpected modification such as methionine oxidation, which adds 16 Da.

Coupling the two techniques as LC-MS lets each chromatographic peak be identified by mass, which is especially useful for longer or aggregation-prone sequences such as Amyloid Beta 1-42.

Where you will see it

Each batch certificate of analysis lists the theoretical mass, the observed mass and the ionisation method, often with the spectrum attached. On product pages such as Kisspeptin-10 the theoretical molecular weight is given so that you can compare it with the certificate. For a side-by-side explanation of both methods, see our article on peptide purity testing by HPLC and MS.

Research peptides where Mass Spectrometry matters

  • Sealed glass vial of lyophilized Tirzepatide research peptide, 30 mg, on a navy background

    CAS 2023788-19-2

    In stock

    Tirzepatide

    Dual GIP/GLP-1 receptor agonist peptide studied in metabolic research, supplied as a 30 mg lyophilized vial for in-vitro and analytical work.

    Purity
    Per batch COA
    Vial
    30 mg

    TT$2,000.00indicative

  • Sealed glass vial of lyophilized Retatrutide research peptide, 20 mg, on a navy background

    CAS 2381089-83-2

    In stock

    Retatrutide

    Investigational GIP, GLP-1 and glucagon triple receptor agonist peptide, supplied as a 20 mg lyophilized vial for in-vitro metabolic research.

    Purity
    Per batch COA
    Vial
    20 mg

    TT$2,200.00indicative

  • Sealed glass vial of lyophilized Tesamorelin research peptide, 10 mg, on a navy background

    CAS 218949-48-5

    In stock

    Tesamorelin

    Synthetic GHRH analogue: the 44-residue human GHRH sequence with an N-terminal trans-3-hexenoyl group, supplied as a 10 mg lyophilized vial.

    Purity
    Per batch COA
    Vial
    10 mg

    TT$1,200.00indicative

  • Sealed glass vial of lyophilized Wolverine Blend, a BPC-157 and TB-500 research peptide blend, on a navy background

    CAS 137525-51-0 / 885340-08-9

    In stock

    Wolverine Blend

    20 mg lyophilized research blend of BPC-157 (10 mg) and TB-500 (10 mg, N-acetyl thymosin β4 17-23), two peptides studied in tissue-repair research models.

    Purity
    Per batch COA
    Vial
    20 mg (10 mg BPC-157 + 10 mg TB-500)

    TT$1,300.00indicative